An administrator has been tasked with recommending a principal storage type for a new cluster within an
existing VMware Cloud
Foundation (VCF) Workload Domain.
The following information has been provided:
• The customer has a 25GbE capable network.
• The customer has an existing 3rd party storage solution that supports connectivity by either FibreChannel and NFS
• The new cluster will consist of two host servers that will be recycled from a previous project.
• Each of the host servers have the following configuration:
o One 500GB Enterprise-grade SSD drive.
o Two 2-Port IOGbE network cards.
• There is no budget for additional hardware.
Which approach should the administrator recommend for the principal storage type?
• The customer has a 25GbE capable network.
• The customer has an existing 3rd party storage solution that supports connectivity by either FibreChannel and NFS
• The new cluster will consist of two host servers that will be recycled from a previous project.
• Each of the host servers have the following configuration:
o One 500GB Enterprise-grade SSD drive.
o Two 2-Port IOGbE network cards.
• There is no budget for additional hardware.
Which approach should the administrator recommend for the principal storage type?
Show answerHide answer
Correct answer: C NFS v3
Explanation
Explanation:This question tests knowledge of VMware Cloud Foundation 9.0 principal storage requirements for a minimum configuration. The key constraints are only 2 hosts and no budget for additional hardware. Standard hyperconverged storage (like vSAN) or Fibre Channel typically requires at least 3 hosts. NFS v3 is the only option supported for this minimal scenario .
✔️ Option C (NFS v3):
VCF 9.0 supports NFS v3 as a principal storage solution for clusters, including minimal configurations with only 2 hosts . Since the customer has an existing NFS-capable array and only two recycled hosts, NFS v3 fits the hardware constraints (no need for additional shared storage hardware) and meets the connectivity requirement via 10GbE .
❌ Option A (Fibre Channel):
While Fibre Channel is supported as principal storage in VCF 9.0, it typically requires a minimum of 3 hosts . Additionally, the hosts provided lack Fibre Channel HBAs (only 10GbE network cards are listed), and the budget does not allow for purchasing new adapters.
❌ Option B (NFS v4.1):
NFS v4.1 is supported, but primarily as a supplemental storage type for workload domains, not as principal storage for new clusters in automated greenfield deployments . Given the customer requires principal storage for this new cluster, NFS v3 is the more compatible and straightforward choice.
❌ Option D (Fibre Channel over Ethernet):
FCoE is not listed as a supported principal storage model for workload domains in VCF 9.0 . It also requires specific hardware convergence (Converged Network Adapters) not present in the provided server configuration and would fail to meet the deployment requirements.
🔧 Reference:
→ Broadcom TechDocs: Storage Models – Confirms NFS v3 supports principal storage for management domains and VI workload domains.
→ VMware Blog: VCF 9 Now Ready For All Storage – Details support for NFS v3 as principal storage in greenfield deployments.