Which of the following is required for a cooling tower or evaporative condenser in Water
Efficiency Prerequisite, Indoor Water Use Reduction?
Show answerHide answer
Correct answer: DMakeup water meters, conductivity controllers and overflow alarms
Explanation
Explanation:
Makeup water meters, conductivity controllers and overflow alarms
According to the Water Efficiency Prerequisite for Indoor Water Use Reduction, cooling
towers and evaporative condensers must be equipped with makeup water meters,
conductivity controllers and overflow alarms to reduce water consumption and prevent
water waste. These devices help monitor and control the water quality, flow rate and level
of the cooling system, and alert the operators of any malfunctions or leaks.
References: As per the LEED AP Building Design + Construction (LEED AP BD+C) V4
resources, the installation of makeup water meters, conductivity controllers and overflow
alarms is a requirement for cooling towers and evaporative condensers under the Water
Efficiency Prerequisite for Indoor Water Use Reduction. This prerequisite aims to reduce
indoor water consumption by setting baseline and efficiency standards for fixtures, fittings,
appliances, equipment and processes. For cooling towers and evaporative condensers, the
prerequisite also requires efficient drift eliminators that reduce drift to a maximum of
0.002% of recirculated water volume for counterflow towers and 0.005% of recirculated
water flow for cross-flow towers. For more detailed information, you can refer to the webbased
reference guide in the credit library at USGBC’s official website.
Question 22Choose 1
According to the Integrative Process Credit, the discovery phase of energy-related systems
should identify
Show answerHide answer
Correct answer: Aventilation rates
Explanation
Explanation: According to the LEED v4 Reference Guide for Building Design and
Construction, the discovery phase of energy-related systems should identify ventilation
rates, along with other factors such as building orientation, envelope attributes, lighting
levels, plug and process loads, and programmatic and operational parameters1. These
factors should be used to create a preliminary “simple box” energy model to evaluate the
energy performance of the building and explore potential strategies to reduce energy use1.
The other options are not relevant for the discovery phase of energy-related systems.
Functional performance tests are part of the implementation phase1. Thermal comfort
ranges are related to indoor environmental quality2. Transportation options are related to
sustainable sites3. References: IP Credit Integrative Process, LEED v4 Reference Guide
for Building Design and Construction4123
Question 23Choose 1
Selecting a high-reflectance interior paint which is compliant with South Coast Air Quality
Management District (SCAQMD) Rule 1113 can help contribute towards which two credits?
Explanation: Selecting a high-reflectance interior paint that meets the SCAQMD Rule
1113 can help contribute towards two credits: Indoor Environmental Quality Credit, Low-
Emitting Materials and Indoor Environmental Quality Credit, Interior Lighting. The first credit
requires that interior paints and coatings comply with the VOC content limits specified by
the SCAQMD Rule 1113 or equivalent standards to reduce indoor air contaminants that are
odorous, irritating, and/or harmful to the comfort and well-being of installers and
occupants1 The second credit aims to provide high-quality lighting that supports visual
acuity and occupant comfort, and that responds to the needs of the space and its users.
One of the strategies to achieve this credit is to use light-colored finishes with a minimum
reflectance of 0.7 for ceilings, 0.5 for walls, and 0.2 for floors to increase the effectiveness
of daylighting and electric lighting systems2 References: 1: LEED v4 Reference Guide for
Building Design and Construction, Indoor Environmental Quality Credit: Low-Emitting
Materials, page 692. 2: LEED v4 Reference Guide for Building Design and Construction,
Indoor Environmental Quality Credit: Interior Lighting, page 715.
Question 24Choose 1
For schools intended for grades eight and below (or ages 14 and below), which of the
following scenarios would demonstrate compliance with Location and Transportation
Credit, Access to Quality Transit, Schools, Option 2. Pedestrian Access?
Show answerHide answer
Correct answer: B50% of the students live no more than a 3/4 mi. (1.20 km) walking distance from a
functional entry of a school building
Explanation
Explanation: For schools intended for grades eight and below (or ages 14 and below), Option 2.
Pedestrian Access requires that at least 50% of the students live no more than a 3/4 mi.
(1.20 km) walking distance from a functional entry of a school building. This option aims to
encourage schools to locate in areas where students can walk or bike to school, reducing
vehicle trips and emissions, and promoting physical activity and health. Option 2 is
available only for projects that do not meet the requirements of Option 1. Transit-Served
Location, which requires access to quality transit service within a 1/4 mi. (400 m) walking
distance for at least 50% of the students.
Question 25Choose 1
Which of the following sinks is classified as a private lavatory faucet under Water Efficiency
Credit, Indoor Water Use Reduction?
Show answerHide answer
Correct answer: CA sink in a hotel room bathroom
Explanation
Explanation:
A sink in a hotel room bathroom is classified as a private lavatory faucet under Water
Efficiency Credit, Indoor Water Use Reduction. According to the LEED v4 BD+C Reference
Guide, a private lavatory faucet is defined as “a faucet that is not generally accessible and
is used only by the building’s occupants and not by the public or visitors” 1. A sink in an
office restroom, a school classroom, or a shared office restroom are examples of public
lavatory faucets, which have different baseline flow rates and requirements. References:
LEED v4 BD+C Reference Guide, Water Efficiency Category, WEc Indoor Water Use
Reduction, page 681.
Question 26Choose 1
The project team has decided to substitute the flooring in the school gym with natural
rubber flooring that has met the Sustainable Agriculture Standard. The cost of the
substituted flooring is $80,000. The project will achieve
Show answerHide answer
Correct answer: AMaterials and Resources Credit, Building Product Disclosure and Optimization -
Sourcing of Raw Materials,
Option 2. Leadership Extraction Practices
Explanation
Explanation: Materials and Resources Credit, Building Product Disclosure and
Optimization - Sourcing of Raw Materials, Option 2. Leadership Extraction Practices
Natural rubber flooring is a bio-based material that can contribute to the achievement of
Option 2 of the Sourcing of Raw Materials credit, which requires using products that meet
at least one of the responsible extraction criteria for at least 25%, by cost, of the total value
of permanently installed building products in the project1. By meeting the Sustainable
Agriculture Standard (SAN), the natural rubber flooring demonstrates that it has been
produced in a way that conserves biodiversity, protects natural resources, and enhances
social and economic well-being2. Therefore, the cost of the substituted flooring ($80,000)
can be counted towards the credit threshold.
Question 27Choose 1
A project team is deciding on the impact of a proposed concrete walkway. Which of the
following will be impacted as a result of adding the walkway?
Show answerHide answer
Correct answer: ASite's impervious cover
Explanation
Explanation: Adding a concrete walkway will increase the site’s impervious cover, which is
the percentage of the site area that does not allow water to infiltrate into the ground1.
Impervious cover can affect the site’s stormwater management, heat island effect, and
habitat quality. The project team should consider using permeable paving materials,
vegetated roofs, or rain gardens to reduce the impervious cover and mitigate its impacts2.
The other options are not directly impacted by adding a concrete walkway. Project density
calculations are based on the floor area ratio and the number of occupants, not the site
features3. Erosion and sediment control plan during construction is required for any site
disturbance, regardless of the type of material used4. Air quality as a result of off gassing
that occurs as concrete cures is not a significant issue for outdoor applications, and can be
minimized by using low-emitting concrete products5.
Question 28Choose 1
The project team wants to modify the design of an office building copy room to minimize
the risk of airborne contamination to the surrounding space. The design includes a
separate exhaust, but due to design constraints the partition walls of the room cannot run
deck-to-deck. What can the team do to achieve Indoor Environmental Quality Credit,
Enhanced Indoor Air Quality Strategies?
Show answerHide answer
Correct answer: BProvide a hard-lid ceiling
Explanation
Explanation: The Indoor Environmental Quality Credit, Enhanced Indoor Air Quality
Strategies aims to establish better quality indoor air for the building occupants that
promotes their comfort and well-being1. This credit requires the project team to implement
several strategies to reduce the exposure of occupants and HVAC systems to
environmental tobacco smoke, airborne contaminants, and chemicals1. One of the
strategies is to design and construct all interior partitions to full height (deck-to-deck) or
provide a hard-lid ceiling for spaces where hazardous gases or chemicals may be present
or used2. This strategy helps prevent the migration of contaminants from one space to
another through the plenum3. A copy room is an example of such a space, as it may
contain printers, copiers, toners, and solvents that can emit volatile organic compounds
(VOCs) and particulate matter (PM) into the air4. Therefore, the project team can achieve Indoor Environmental Quality Credit, Enhanced Indoor Air Quality Strategies by providing a
hard-lid ceiling for the copy room.
Question 29Choose 1
An owner has insisted on using a non-native or non-adapted plant species on both the
vegetated roof and ground level. What Sustainable Sites credit will this decision impact the
most?
Show answerHide answer
Correct answer: ASite Development-Protect or Restore Habita
Explanation
Explanation:
Using a non-native or non-adapted plant species on both the vegetated roof and ground
level will impact the Sustainable Sites credit Site Development-Protect or Restore Habitat
the most. This credit requires that at least 20% of the site area (excluding building footprint)
or 5% of the site area (including building footprint) must be vegetated with native or
adapted plants. Non-native or non-adapted plants do not qualify for this credit and may also
have negative impacts on the local ecosystem and biodiversity. The other credits are not
directly affected by the choice of plant species, although they may have other requirements
related to vegetation, such as shading, reflectance, or lighting. References: LEED v4 BD+C
Reference Guide, Sustainable Sites Category, SSc Site Development-Protect or Restore
Habitat, page 648.