ASCP certification · Exam ASCP-MLT

ASCP-MLT Mock Exam Page 3

MEDICAL LABORATORY TECHNICIAN - MLT(ASCP)

Free ASCP-MLT mock exam questions 21–30, each with the answer and an explanation.

20 questions · 33 minutes · free, no sign-up

Free ASCP-MLT questions

21–30 of 168 free
Question 21 Choose 1
Transpeptidase enzymes catalyze the final stage of peptidoglycan synthesis during cell wall formation. Beta-lactam antibiotics bind with these enzymes, interfering with their function. The transpeptidase enzymes are also referred to as PBP's, or penicillin-binding proteins. Beta-lactam antibiotics interfere with cell wall synthesis by:
Show answerHide answer

Correct answer: D All of the above

Question 22 Choose 1
Following an accidental needlestick, the person should be tested for all of the following except:
Show answerHide answer

Correct answer: D hepatitis A virus (HAV)

Question 23 Choose 1
Troponin is potentially more specific for myocardial damage than CK-MB and stays elevated longer. It may eventually replace CK-MB as the standard marker of myocardial damage. In addition, troponin T has been known to be elevated in the setting of even mild degrees of renal failure. Troponin and CK-MB both tend to rise approximately 3 hours after a MI (hence why the correct answer is "A", since it is false); however, troponins can stay elevated up to 2 weeks as CK-MB tends to return to baseline around 36 hours.
Chemistry
Which of the following statements is FALSE regarding troponin?
Show answerHide answer

Correct answer: A It rises much sooner after an MI than CK-MB

Question 24 Choose 1
Myoglobin release is strongly associated with muscle damage; therfore, it would most closely match a diagnosis of massive muscle trauma in this question. Myoglobinuria is MOST likely to be noted in urine specimens from patients with which of the following disorders?
Show answerHide answer

Correct answer: C massive muscle trauma

Question 25 Choose 1
Monoclonal antibodies are monospecific antibodies that are the same because they are made by one type of immune cell which are all clones of a unique parent cell, also called a hybrid cell line, which usually arise from a hybridoma. The fusion of a specific antibodyproducing lymphocyte with a myeloma cell will multiply to become a source of pure monoclonal antibody. This is often used in the manufacturing process for monoclonal antibody reagents. Monoclonal antibodies are usually manufactured in vitro by using:
Show answerHide answer

Correct answer: C Hybridomas

Question 26 Choose 1
First, the RBC indices must be calculated. The MCV ((Hct/RBC) x 10) = 71 fL. Since the reference range for the MCV is 80-100 fL, this anemia would be classified as microcytic. The MCH ((Hgb/RBC) x 10) = 19.3 pg. Since the reference range for the MCH is 27-33 pg, this would be considered hypochromic. Finally, the MCHC ((Hgb/Hct) X 100) = 27%. Since the normal range for the MCHC is 33%-36%, this would indicate hypochromia which correlates with the MCH findings. The correct answer is therefore microcytic, hypochromic anemia.
A patient is admitted to the emergency room with lethargy and pallor. The CBC results are as follows:
RBC = 4.1 x 1012/L
Hemoglobin = 7.9 g/cL
Hematocrit = 29%
How would you classify this anemia?
Show answerHide answer

Correct answer: A microcytic, hypochromic

Question 27 Choose 1
Provide the equivalent measurement for 1 decimeter
Show answerHide answer

Correct answer: C 100 millimeters

Question 28 Choose 1
Caffeine benzoate solution is used to split the unconjugated bilirubin protein complex releasing the bilirubin so that it can react with diazotised sulphanilic acid. The tartrate buffer creates an alkaline solution and converts the red acid bilirubin to a green coloured compound which can be measured spectrophotometrically. Which substance is used in the Jendrassik-Grof method to accelerate the reaction of unconjugated bilirubin with the diazo reagent?
Show answerHide answer

Correct answer: B N-butanol

Question 29 Choose 1
Which of these advancements in the clinical laboratory has led to concerns about patient privacy
Show answerHide answer

Correct answer: C computers

Question 30 Choose 1
Calculation:
Cells Counted (in this case the average of both sides) X dilution factor (in this case 100) / # of squares counted (in this case 9) X area of each square (1mm2) X 0.1mm (depth factor) So, in this problem:
158 x 100 / 9 x 1 x 0.1mm = 17555.55/mm3 (can be converted to 17.5 x 109/L*)
*There are 1,000,000 mm3 in a liter (L). So 17555.55 X 1,000,000 = 17.5 x 109/L
A manual white blood cell count was performed by the hematology technologist. The cell counts for both sides were 152 and 164 respectively. All nine large squares were counted on each side. The dilution for this kit was pre-measured at 1:100. What should the technologist report as the white cell count?
Show answerHide answer

Correct answer: B 17.5 x 10^9/L

Full mock exam

Sit the ASCP-MLT exam before exam day

Full-length mocks with the same number of questions and the same time limit as the real ASCP-MLT exam. Every attempt draws a new set of questions from the full bank, so you can keep going until you pass comfortably.

Get full ASCP-MLT mock exam
  • 65questions per mock
  • 105 mintime limit
  • 561questions in the bank
  • Newmock on every attempt