CompTIA certification · Exam SK0-005

SK0-005 Mock Exam Page 15

CompTIA Server+

Free SK0-005 mock exam questions 141–146, each with the answer and an explanation.

20 questions · 20 minutes · free, no sign-up

Free SK0-005 questions

141–146 of 146 free
Question 141 Choose 1
An administrator has been asked to verify that all traffic egressing from a company is secured. The administrator confirms all the information that is sent over the network is encrypted. Which of the following describes the type of traffic being encrypted?
Show answerHide answer

Correct answer: D Data in transit

Explanation

Explanation

The key to this question is understanding the specific term for data that is actively moving across a network and the requirement to secure it during that movement.

Correct Option

D. Data in transit

This term, also known as "data in motion," precisely describes information that is actively being transmitted from one location to another across a network. The scenario explicitly mentions "traffic egressing from a company" and "sent over the network." The act of encrypting this data ensures its confidentiality and integrity while it is traveling, protecting it from eavesdropping or modification. Verifying that all such traffic is encrypted is a core security practice for protecting data as it leaves the corporate boundary.

Incorrect Options

A. Network encapsulation

Reason for Incorrectness:
Encapsulation is a networking process where data is wrapped with protocol headers and trailers to direct it across a network (e.g., adding IP and TCP headers). While some encapsulation protocols can include encryption (like IPsec), encapsulation itself is not synonymous with the data being encrypted. It is a general networking function, not a description of the secured data.

B. Off-site data

Reason for Incorrectness:
This term describes the final location of data (e.g., in a backup data center or cloud storage), not its state. Data is "off-site" whether it is at rest or was previously in transit. The question is specifically about the state of the data as it is being sent over the network.

C. Secure FTP

Reason for Incorrectness:
Secure FTP (such as FTPS or SFTP) is a specific protocol or method used to encrypt a certain type of traffic (file transfers). It is an example of how to protect "data in transit," but it is not the overarching term itself. The question describes a company-wide verification of all egress traffic, which is much broader than just a single protocol like FTP.

Reference:
This distinction is fundamental in data security. Security controls are categorized based on the data's state: Data in Transit (moving over a network), Data at Rest (stored on a medium), and Data in Use (being processed by a CPU). The scenario describes a control for securing data in transit.
Question 142 Choose 1
A technician has beer tasked to install a new CPU. Prior to the retaliation the server must be configured. Which of the following should the technician update?
Show answerHide answer

Correct answer: B The BIOS

Explanation

Explanation

When installing a new CPU, the system firmware must properly support and recognize the new processor.
Updating the BIOS ensures that the server can correctly identify the CPU architecture, apply the necessary microcode, and enable all features such as power management and CPU instructions.
Without a BIOS update, the server may fail to boot, misidentify the CPU, or operate with reduced performance and stability.
Updating the BIOS is a standard preparation step for CPU upgrades to ensure full compatibility and reliable operation.

Why the Other Options Are Incorrect

Option A: The RAID card

The RAID card controls storage arrays and has no role in CPU compatibility or recognition.
Updating the RAID card firmware would not prepare the server for a new processor.

Option C: The backplane

The backplane connects drives and sometimes expansion components but does not handle CPU functionality.
Updating or replacing a backplane does not help with CPU installation requirements.

Option D: The HBA

A Host Bus Adapter is related to connecting storage networks such as SANs.
It does not affect CPU support and therefore does not need an update before installing a new processor.

Relevant Technical Concept
Processor compatibility is controlled at the firmware level. BIOS updates provide CPU microcode and support for new hardware generations, enabling proper boot and system stability.
Question 143 Choose 1
A server administrator made a change in a server's BIOS in an attempt to fix an issue with the OS not turning on. However, the change did not successfully correct the issue. Which of the following should the server administrator do NEXT?
Show answerHide answer

Correct answer: C Reverse the latest change made to the server and reboot.

Explanation

Explanation

The next logical step for the server administrator is to reverse the single variable they changed to see if the system returns to its previous state, following basic troubleshooting best practices.

Correct Action:Reverse the Latest Change

Troubleshooting methodology dictates that when a change is made to fix a problem, and that change fails to resolve the issue, the first action should be to undo that change.
The administrator made a change to the server's BIOS (Basic Input/Output System) to address an OS startup problem.
Since the change did not work, the administrator must reverse the BIOS setting back to its original configuration. This eliminates the BIOS change as a potential cause of the problem and ensures the server is not stuck due to an incorrect, new configuration.
After reversing the change, the server should be rebooted to test if the original (or a different) error state is reached. This is the simplest and safest next step.

Why Other Options Are Incorrect

A. Reinstall the server OS in repair mode while maintaining the data.

Reinstalling the OS, even in repair mode, is a drastic step that should be taken only after exhausting simpler, less intrusive options.
Since the administrator just changed a BIOS setting, the OS files themselves are unlikely to be the primary cause.
This action risks data integrity and consumes unnecessary time.

B. Flash the BIOS with the most recent version.

Flashing (updating) the BIOS is a procedure that carries inherent risk (e.g., bricking the motherboard if interrupted).
It should only be performed if the current BIOS is known to be the cause of the problem, and certainly not immediately after a failed configuration change.
Reversing the specific setting is much safer.

D. Restart the server into safe mode and roll back changes.

Safe Mode is an OS-level diagnostic state.

Since the issue is described as the OS not turning on (suggesting the failure occurs before or during the bootloader or core OS loading phase), the server may not even be able to successfully reach a state where Safe Mode can be selected or initiated.

Furthermore, the change that failed was in the BIOS, which is outside the control of the operating system's Safe Mode rollback features.
Question 144 Choose 1
An administrator needs to increase the size of an existing RAID 6 array that is running out of available space. Which of the following is the best way the administrator can perform this task?
Show answerHide answer

Correct answer: D Replace the array drives one at a time and then expand the array.

Explanation

Explanation

RAID 6 provides fault tolerance for up to two drive failures using dual parity, but it does not inherently support online capacity expansion (OCE). To increase usable space in an existing RAID 6 array, the administrator must first increase the physical capacity of the array members (by replacing smaller drives with larger ones), then trigger a logical volume expansion. The safest and most widely supported method across hardware RAID controllers (e.g., Broadcom, LSI, Dell PERC, HPE Smart Array) is to replace drives one at a time, allow full rebuild/redundancy restoration after each replacement, and finally expand the logical array once all drives are upgraded. This maintains fault tolerance throughout the process.

Correct Answer

Replace the array drives one at a time and then expand the array follows a proven, low-risk procedure:

Insert a larger drive into a hot-swap bay.
The controller marks the old drive for removal and rebuilds data + parity onto the new (larger) drive.
Repeat for each drive, waiting for full rebuild (RAID 6 remains tolerant of one additional failure during this phase).
Once all drives are replaced, use the RAID management utility (e.g., MegaRAID Storage Manager, perccli, ssacli) to expand the array—extending the stripe size across the new capacity.
Finally, grow the filesystem (e.g., xfs_growfs, resize2fs) to use the new space.
This method avoids downtime, preserves data, and is explicitly supported by enterprise RAID vendors.

Incorrect Options

A. Replace all the array drives at once and then expand the array.
Replacing all drives simultaneously destroys the array—there is no parity or data to rebuild from. This results in total data loss and requires a full restore from backup. It violates RAID redundancy principles.

B. Expand the array by changing the RAID level to 6.
The array is already RAID 6. Changing to the same level does nothing. RAID level migration (e.g., RAID 5 → 6) adds parity but does not increase capacity unless larger drives are present.

C. Expand the array by changing the RAID level to 10.
RAID 10 (1+0) requires an even number of drives and a different striping/mirroring layout. Converting RAID 6 → RAID 10 is not universally supported, often requires backup/restore, and may reduce usable capacity (50% efficiency vs. ~80% in RAID 6). It does not address the root need—adding space via larger drives.

References:
Broadcom MegaRAID – Online Capacity Expansion (OCE) and Drive Replacement Guide
HPE Smart Array – RAID Level Migration and Capacity Expansion Procedures
LSI/Avago RAID Management – Replacing and Expanding RAID 6 Arrays
SNIA Dictionary – RAID 6 Definition and Rebuild Process
Question 145 Choose 1
An administrator is troubleshooting a failed NIC in an application server. The server uses DHCP to get all IP configurations, and the server must use a specific IP address. The administrator replaces the NIC, but then the server begins to receive a different and incorrect IP address. Which of the following will enable the server to get the proper IP address?
Show answerHide answer

Correct answer: A Modifying the MAC used on the DHCP reservation

Explanation

Explanation

The core of this problem is the combination of two requirements: the server must get its IP via DHCP, but it must also always receive the same, specific IP address. The failure occurred because the unique identifier linking the server to that IP address changed when the hardware was replaced.

Correct Option

A. Modifying the MAC used on the DHCP reservation

This is the direct and correct solution. A DHCP reservation is a configuration on the DHCP server that permanently assigns a specific IP address to a unique identifier, which is typically the MAC (Media Access Control) address of the network card.
When the original NIC failed, it took its unique MAC address with it. The new NIC has a new, different MAC address. The DHCP server sees a request from an unknown MAC and, therefore, assigns it a random available IP from the pool instead of the reserved one.
By updating the existing DHCP reservation to use the new NIC's MAC address, the DHCP server will once again recognize the server's request and provide it with the correct, specific IP address.

Incorrect Options

B. Updating the local hosts file with the correct IP address

Reason for Incorrectness:
The hosts file is used for local hostname-to-IP resolution. It does not control how the server obtains its own IP address configuration. The server is configured to use DHCP, so it will ignore a manually set IP in the hosts file during the network initialization process.

C. Modifying the WWNN used on the DHCP reservation

Reason for Incorrectness:
A WWNN (World Wide Node Name) is a unique identifier used in Fibre Channel storage area networks (SANs). It is relevant for storage connectivity (like HBA cards) and has nothing to do with Ethernet networking or DHCP, which uses MAC addresses for identification.

D. Updating the NIC to use the correct WWNN

Reason for Incorrectness:
This is incorrect for the same reason as option C. A standard Ethernet NIC does not have a configurable WWNN; that is a Fibre Channel concept. Furthermore, a DHCP server would not recognize or use a WWNN for assigning an IP address.

Reference:
This solution is based on standard DHCP server administration. Reservations are the standard method for ensuring a DHCP client receives a consistent IP address, and they are bound to the client's MAC address.
Question 146 Choose 1
An administrator has been asked to increase the storage capacity of a stand-alone file server but no further expansion slots are available. Whichof the following would be the FASTEST solution to implement with no downtime?
Show answerHide answer

Correct answer: D Connect the server to a SAN

Explanation

Explanation

The server requires additional storage, but it has no free expansion slots, and the upgrade must be done fast with zero downtime. Connecting the server to a Storage Area Network (SAN) allows it to immediately access new storage volumes over a high-speed network connection. This can be configured dynamically while the system is still running, ensuring continuous availability of the file server to users.

A SAN provides scalable capacity and performance appropriate for an actively used file server environment, making it the quickest and most seamless storage expansion method.

Why the Other Options Are Incorrect

Option A: Configure a RAID array

A new RAID configuration would require additional drives and available drive bays, which are not present. Even if existing drives were reconfigured, RAID creation or migration often requires downtime and data rebuild time. It does not solve the lack of expansion slots.

Option B: Replace the current drives with higher-capacity disks

This process involves physically removing current drives, reinstalling larger ones, and restoring the existing data. That means:
Data migration downtime
Potential raid rebuild
Increased risk of data loss if a drive fails during migration
This is far from the fastest option and would interrupt service availability.

Option C: Implement FCoE for more storage capacity

Fibre Channel over Ethernet is merely a protocol that provides a method to connect to a SAN. Implementing FCoE alone does not increase storage; it also requires specialized switches, adapters, and complex configuration. It does not provide an immediate or simple solution without downtime.

Relevant Technical Concept
SAN technology enables dynamic storage provisioning, presenting network-attached block storage as if it were directly connected — ideal for rapid expansion with no system interruption.

That's the last free question

You've seen the free 30% (146 of 493 questions). Full access unlocks every question and full-length SK0-005 mock exams (90 questions, 90 minutes), a different mock on every attempt.

Unlock full mock exam
Full mock exam

Sit the SK0-005 exam before exam day

Full-length mocks with the same number of questions and the same time limit as the real SK0-005 exam. Every attempt draws a new set of questions from the full bank, so you can keep going until you pass comfortably.

Get full SK0-005 mock exam
  • 90questions per mock
  • 90 mintime limit
  • 493questions in the bank
  • Newmock on every attempt