PECB certification · Exam ISO-14001-Lead-Auditor

ISO-14001-Lead-Auditor Mock Exam Page 2

PECB Certified EMS ISO 14001 Lead Auditor Exam

Free ISO-14001-Lead-Auditor mock exam questions 11–20, each with the answer and an explanation.

20 questions · 30 minutes · free, no sign-up

Free ISO-14001-Lead-Auditor questions

11–20 of 27 free
Question 11 Choose 3

An internal auditor of a manufacturer of aluminium products for the car industry raised a nonconformity against section 6.2.2 of ISO 14001 in Report IA202. The nonconformity (NC3) stated:

"Top management has not analysed why none of the environmental objectives set for the last year have been met."

A third-party auditor reviewing the internal audit process came across the nonconformity and found that no corrective action was documented. The EMS Manager confirmed no action had been taken, but added he expected a number of objectives to be achieved in the next three months so there was no need for further action. He explained in confidence that the organisation was fighting a takeover bid and resources for environmental projects had been cut.

From the information, select three non-conformities options that the auditor could raise to ISO 14001.

Show answerHide answer

Correct answer: C, E, F 6.2.2 - Actions were not taken to fully implement the environmental objectives set by management7.1 - The top management failed to provide the resources needed to meet the objectives10.2.a - Management failed to take corrective action to deal with the audit nonconformity

Question 12 Choose 3

You are conducting a Stage 2 certification audit of VitalSpark, a pharmaceutical organisation manufacturing vitamins and other healthcare medicines.

In a separate area in the centre of their large site, a supplier produces oxygen supplies piped directly into the manufacturing processes of VitalSpark. They also deliver oxygen in bulk tankers to other customers. When you review the environmental aspects register, you find that the only environmental aspect recorded for this arrangement relates to the heavy goods vehicles of the supplier transiting the site.

You ask the EMS Manager about the environmental consequences to VitalSpark of this arrangement and are told that they are not significant since the supplier has its own services for water, sewage, waste and energy. The EMS Manager tried unsuccessfully to

communicate with the supplier who is located inside the VitalSpark site and outside the scope of the EMS.

After gathering more evidence, you note down findings against several clauses of ISO 14001. Determine which three of the findings stated are non-conformities.

Show answerHide answer

Correct answer: C, G, H Documentation of environmental impacts was missing for the supplier of oxygen. (Clause 6.1.2)The internal audit programme does not include processes for control of subcontractor transport movements. The audit programme does not cover the full environmental management system. (Clause 9.2.2)The organisation has failed to include in the EMS scope the activities, products and services associated with suppliers and contractors performing their activities in its own site. (Clause 4.3)

Question 13 Choose 2

An audit team leader arrives at a steel fabrication organisation that manufactures fire escape stairs to carry out a Stage 2 certification audit. At a meeting with the EMS Manager, she is told that they have won their biggest contract from a construction organisation to manufacture and install fire escape stairs. They appointed a subcontractor to perform the installation work. The EMS Manager wants the ISO 14001 audit extended to cover the installation site and has set environmental objectives for the subcontractor in line with the EMS policy below:

“It is the policy of the organisation to protect the environment by acting with responsibility at all times, to comply with relevant legislation and to set objectives that will enhance our environmental performance.”

The auditor seeks evidence of the awareness of subcontractor personnel of the environmental policy set by management.

From the following options, select two issues that all subcontractor personnel should be aware of relating to the organisation’s environmental policy.

Show answerHide answer

Correct answer: A, D Complying with legal requirementsCommitment to environmental protection

Explanation

The correct answers are A and D.

This question relates mainly to ISO 14001:2015 Clause 7.3 — Awareness and Clause 5.2 — Environmental policy.

Persons doing work under the organisation’s control, including subcontractor personnel where relevant, need to be aware of the organisation’s environmental policy. In this scenario, the environmental policy specifically includes two clear commitments:

A. Complying with legal requirements — Correct

The policy states that the organisation will “comply with relevant legislation.” Therefore, subcontractor personnel must be aware that their work must comply with applicable legal and environmental requirements. This is especially important because installation work may involve paint, waste, emissions, spill risks, drainage controls, and site environmental rules.

D. Commitment to environmental protection — Correct

The policy states that the organisation will “protect the environment by acting with responsibility at all times.” Therefore, subcontractor personnel should understand their responsibility to protect the environment while carrying out installation activities.

The other options are not the best answers:

B. Continual improvement of the EMS — Incorrect in this context

Continual improvement is an ISO 14001 policy requirement generally, but the policy text given in the question focuses on protecting the environment, complying with legislation, and setting objectives to enhance environmental performance. It is not one of the two clearest issues directly stated in the provided policy wording.

C. Addressing customer complaints — Incorrect

Customer complaints may be relevant to performance evaluation or corrective action, but they are not a stated commitment in the environmental policy.

E. Communicating with trade unions — Incorrect

This is not an environmental policy awareness requirement in the scenario.

F. Conducting environmental risk assessments — Incorrect

Risk assessment may be part of EMS planning, but the question asks what subcontractor personnel should be aware of in relation to the environmental policy, not what technical EMS activities they must conduct.

Therefore, the two correct issues are A. Complying with legal requirements and D. Commitment to environmental protection.

Question 14 Choose 6

A large public library established an EMS in accordance with ISO 14001 requirements, which was third-party certified 10 years ago. You are performing the second surveillance audit of the third certification cycle. The audit plan included an audit of the Director as the last interview before the closing meeting.

During the interview with the Director, you audit clause 6.2 (Objectives and planning to achieve them). The dialogue is as follows:

You: Could you please tell me which environmental objectives were defined for last year and show evidence of their achievement?

Director: Yes. We had defined three objectives. As you can see from our Annual Plan, one of them was to separate our waste into four categories: paper, plastics, metals, and food. Before, we had only three (plastic and paper were disposed of together). The deadline is in six months. We developed an Action Plan to achieve this objective.

Which six of the questions would you ask related to this objective?

Show answerHide answer

Correct answer: B, D, E, F, I, J What resources did you need?Did you communicate it to relevant personnel?Is it consistent with the environmental policy?Did you keep any documented information?How is it being monitored?Is it measurable?

Explanation

In accordance with ISO 14001:2015 Clause 6.2.1 (Environmental objectives) and Clause 6.2.2 (Planning actions to achieve environmental objectives), the standard sets explicit criteria for establishing objectives and determining how to achieve them.

To audit compliance against Clause 6.2 in this scenario, an auditor must evaluate six key criteria explicitly required by the standard:

What resources did you need? (Option B / Clause 6.2.2 b): Determines whether necessary resources (e.g., bins, signage, contractor services) were allocated.

Did you communicate it to relevant personnel? (Option D / Clause 6.2.1 f & Clause 7.4): Evaluates if objectives were effectively communicated across relevant functions and levels.

Is it consistent with the environmental policy? (Option E / Clause 6.2.1 a): Verifies alignment with top management commitments to pollution prevention and compliance.

Did you keep any documented information? (Option F / Clause 6.2.1): Confirms the mandatory requirement to maintain documented information on environmental objectives.

How is it being monitored? (Option I / Clause 6.2.1 e & Clause 6.2.2 e): Audits how progress is evaluated, including indicators and integration into business processes.

Is it measurable? (Option J / Clause 6.2.1 b): Checks whether the objective is measurable (if practicable) or capable of performance evaluation.

Questions regarding formal Director approval, specific manager designation, hypothetical deadline failure consequences, or update schedules are administrative considerations not directly dictated as core clause requirements.

References: ISO 14001:2015 Clause 6.2.1 (Environmental objectives), Clause 6.2.2 (Planning actions to achieve environmental objectives), Annex A.6.2, and CQI-IRCA ISO 14001 Lead Auditor Curriculum (Auditing Environmental Objectives).

Question 15 Choose 1

An audit team leader arrives at a steel fabrication organisation that manufactures fire escape stairs to carry out a Stage 2 certification audit. At a meeting with the EMS Manager, she is informed that they have secured their largest contract from a construction organisation to manufacture and install fire escape stairs. They appointed a subcontractor to perform the installation work. The EMS Manager wants the ISO 14001 audit extended to cover the installation site.

During the audit, a team member found that several complaints had been made to the organisation regarding their installation operators being seen to dispose of excess paint into the site drains, which breached legal requirements. The EMS Manager blames the contractors they had to take on because of the big contract. The auditor raises a nonconformance against clause 8.1 of ISO 14001.

Which one of the following statements would support this finding?

Show answerHide answer

Correct answer: A There was no statement in the installation contract of the need for the subcontractor to comply with the EMS policy.

Explanation

The correct answer is A.

This finding relates to ISO 14001:2015 Clause 8.1 — Operational planning and control. Clause 8.1 requires the organisation to control or influence outsourced processes and to communicate relevant environmental requirements to external providers, including contractors.

In this case, the installation work was subcontracted, but the environmental impact still occurred as part of the organisation’s activities and contracted work. The disposal of excess paint into site drains created a legal breach and showed that the organisation had not effectively controlled or influenced the outsourced installation activity.

A is correct because a contract is a key way to communicate operational controls and environmental requirements to a subcontractor. If the installation contract did not require the subcontractor to comply with the organisation’s EMS policy or environmental requirements, this supports a nonconformity against Clause 8.1.

The other options are linked to different ISO 14001 clauses:

B relates more closely to Clause 7.3 — Awareness.

C relates more closely to Clause 7.1 — Resources.

D relates more closely to Clause 7.2 — Competence.

Therefore, the statement that best supports a nonconformity against ISO 14001 Clause 8.1 is A.

Question 16 Choose 3

A multi-level shopping centre is open every day to the public from 09:00-21:00. During an external audit of the centre to ISO 14001, you establish that there are 40 vending machines that are permanently switched on. Thirty of them do not sell perishable foodstuffs. You also note that there are eight escalators in the complex that run constantly during public access. When asked about environmental performance improvement objectives, the Centre Manager says that there are plans to increase the natural daylight by installing more skylights, thus saving on lighting costs, but the board has not yet approved the estimated budget for this.

You: I note that energy consumption is a significant environmental aspect in the centre. How do you mitigate the impacts of this?

EMS Manager: We try to reduce our energy costs by negotiating a better deal from the energy company. We are considering changing to one that only supplies electricity from renewable sources.

You: What steps have you taken to reduce overall consumption?

EMS Manager: We conducted awareness training for staff. For example, turning off lights in staff areas not being used.

You: I see that the escalators account for the highest usage of energy. Are there any objectives to try to reduce this?

EMS Manager: No, it would be too costly to change them.

You: How do you measure electricity consumption?

EMS Manager: We have meters installed on each floor of the centre. We take readings every hour, and we plot the consumption graph for every staff shift.

Select three options that would provide evidence of conformance with clause 9.1.1 of ISO 14001.

Show answerHide answer

Correct answer: C, D, F Periodic analysis of the results of meter readings.Certification showing that the meters are calibrated to known standards.A procedure that provides instructions in taking meter readings and using them to plot a graph.

Explanation

The correct answers are C, D and F.

This question relates to ISO 14001:2015 Clause 9.1.1 — Monitoring, measurement, analysis and evaluation.

Clause 9.1.1 requires the organisation to monitor, measure, analyse and evaluate its environmental performance. The organisation must determine what needs to be monitored and measured, the methods for monitoring, measurement, analysis and evaluation, when monitoring and measurement will be performed, and when results will be analysed and evaluated. It must also ensure monitoring and measuring equipment is calibrated or verified, where appropriate.

C. Periodic analysis of the results of meter readings — Correct

The shopping centre is measuring electricity consumption using meters. Analysing meter readings periodically provides evidence that the organisation is evaluating environmental performance, not just collecting data.

D. Certification showing that the meters are calibrated to known standards — Correct

Because the centre relies on electricity meters to measure energy consumption, calibration or verification evidence supports the validity of the measurement results.

F. A procedure that provides instructions in taking meter readings and using them to plot a graph — Correct

This provides evidence that the organisation has defined a method for monitoring and measuring energy consumption and for presenting the data for analysis.

The other options are not the best answers for Clause 9.1.1:

A relates more to competence or awareness, not monitoring and measurement.

B relates to environmental objectives under Clause 6.2, not directly to Clause 9.1.1.

E is not relevant unless office temperature has been identified as something requiring monitoring.

G is an operational improvement action, not evidence of monitoring and measurement.

H may affect energy use, but increased visitor numbers alone do not demonstrate monitoring, measurement, analysis or evaluation.

Therefore, the three items that best demonstrate conformance with ISO 14001:2015 Clause 9.1.1 are C, D and F.

Question 17 Choose 2

You are auditing a regional distribution depot of Park and Spend, a major retail chain. In a corner, you notice a steel drum sitting in a pool of liquid, which is slightly leaking across a passageway which has a barrier to prevent access. You ask the Depot Manager what is in the drum and are told it is hydraulic oil for the forklift trucks. When you ask why it is kept there, you are told that it is not normally kept there, but one of the forklift trucks reversed into it during the previous shift when it was waiting to be moved to a maintenance area. He says that he will get the floor cleaned up right away.

Select the two options that would give you cause for concern in relation to conformance to ISO 14001.

Show answerHide answer

Correct answer: B, E The oil drum was found in the wrong location, where it was exposed to collision with a forklift truck.The oil from the leaking drum may cause ground contamination.

Explanation

In accordance with ISO 14001:2015 Clause 8.1 (Operational planning and control) and Clause 6.1.2 (Environmental aspects), an organization must establish controls to manage significant environmental aspects and prevent environmental damage resulting from operational activities.

Option B is correct because staging or storing hazardous chemical containers in unapproved, vulnerable locations where they are exposed to vehicular traffic demonstrates a breakdown in operational controls and storage procedures (Clause 8.1). Option E is correct because an uncontained, leaking drum of hydraulic oil poses a direct environmental aspect/impact through potential land or ground contamination, or entry into drainage systems if an emergency response is not promptly executed (Clause 6.1.2 / Clause 8.2).

Option A focuses on occupational health and safety (OH & S) fire hazards rather than environmental impact under ISO 14001. Option C relates to operational maintenance and equipment availability, which is a business operational concern rather than an EMS nonconformity. Option D represents a general training recommendation without direct evidence of competence evaluation failure under Clause 7.2. Option F addresses occupational safety (slips and trips), which falls under ISO 45001 (OH & S) rather than the environmental scope of ISO 14001.

References: ISO 14001:2015 Clause 6.1.2 (Environmental aspects), Clause 8.1 (Operational planning and control), Clause 8.2 (Emergency preparedness and response), and CQI-IRCA ISO 14001 Lead Auditor Curriculum (Evaluating Operational Controls and Environmental Aspects).

Question 18 Choose 6

A chain of 10 paint shops in a city has established an EMS following the requirements of ISO 14001, which was third-party certified 10 years ago. You are performing a second-party audit. The audit plan included an interview with the General Manager.

The dialogue was as follows:

You: Hi, good evening. I have seen well-developed environmental risk assessment processes. However, I did not find the identification of emergency situations included in the results of this process. The Environmental Manager could not provide me with an acceptable answer to this question.

GM: The EM joined us two months ago, and he may not know some decisions we made some time ago, when we first certified our EMS. During those days, I met with all 10 supervisors and asked them what the emergencies were that they feared most. They unanimously said: fire. That was it. This is the only emergency we care of. As far as I remember we do not test the plan very often because the supervisors of all our 10 shops know it very well. The auditors of our certification body accepted this. We did not have a fire in the last 10 years.

What evidence would you need to review to determine conformity with ISO 14001 in this scenario? Select six.

Show answerHide answer

Correct answer: A, B, D, F, G, H Shops that have tested the plan in the last 10 yearsReplacements of supervisors of each shop when they are absent, for any reasonGeneral competence records of all 10 supervisorsReports of the management reviewsRecords of the specific fire combat training of workersResults of the inspection of fire extinguishers

Explanation

The correct answers are A, B, D, F, G and H.

This scenario mainly relates to ISO 14001:2015 Clause 8.2 — Emergency preparedness and response, supported by Clause 7.2 — Competence, Clause 7.3 — Awareness, and Clause 9.3 — Management review.

A. Shops that have tested the plan in the last 10 years — Correct

ISO 14001 expects planned emergency response actions to be tested periodically where practicable. Since the General Manager says the plan is not tested very often, the auditor should check which shops have tested the emergency plan and when.

B. Replacements of supervisors of each shop when they are absent — Correct

The General Manager relies heavily on the 10 supervisors knowing the fire emergency plan. The auditor should verify what happens if a supervisor is absent. Emergency response must remain effective regardless of absence, leave, sickness, or shift changes.

D. General competence records of all 10 supervisors — Correct

If supervisors are relied upon to control emergency response, their competence is relevant evidence. The auditor should verify that they are competent to perform the emergency-related responsibilities assigned to them.

F. Reports of the management reviews — Correct

Management review records may show whether emergency preparedness, incidents, changes, resources, test results, improvement needs, and EMS effectiveness have been reviewed. This is important because the emergency decision appears to have been made 10 years ago and may not have been adequately reviewed since.

G. Records of the specific fire combat training of workers — Correct

Workers must have suitable awareness and training related to emergency preparedness and response. For paint shops, fire is a credible emergency situation, so specific fire response training records are relevant evidence.

H. Results of the inspection of fire extinguishers — Correct

Fire extinguishers are part of the emergency response arrangements. Inspection results help confirm that emergency equipment is available, maintained, and suitable for use.

The two options not selected are:

C. Reports of audits from the certification body — Not selected

Previous certification audit reports may provide background, but they do not replace the auditor’s own audit evidence. The current audit must determine present conformity.

E. Signage related to health and safety in each shop — Not selected

Health and safety signage may be useful, but the question is about ISO 14001 EMS conformity and environmental emergency preparedness. It is not one of the strongest pieces of evidence for this EMS issue unless directly linked to environmental emergency response.

Question 19 Choose 2

You have been nominated audit team leader for the second recertification to ISO 14001 of ABC, a public transport organisation in a big city. The audit is planned to take place in two months'time. The audit program manager asks you to review the answer provided by ABC to a nonconformity raised during the last surveillance audit carried out eight months ago. The nonconformity reads as follows: " ABC does not always communicate its relevant environmental requirements to external providers. Evidence: A two-month contract signed with a new external provider of the maintenance for ABC's buses did not contain any relevant environmental requirements. "

Which two would you consider to be the best acceptable corrections from ABC?

Show answerHide answer

Correct answer: A, E We identified environmental aspects related to the external provider's activitiesWe revised the contract signed with the external provider to include environmental requirements

Explanation

In accordance with ISO 14001:2015 Clause 10.2 (Nonconformity and corrective action) and ISO 19011 Clause 6.6, a clear technical distinction exists between a correction (action taken to eliminate a detected nonconformity or mitigate its immediate effect) and a corrective action (action taken to eliminate the root cause and prevent recurrence).

In this scenario, the specific nonconformity is that relevant environmental requirements were not communicated in the bus maintenance contract, and the aspects of that provider were not systematically evaluated:

Option A: Identifying the environmental aspects associated with the external provider's maintenance activities immediately corrects the technical gap regarding operational knowledge under Clause 6.1.2 and Clause 8.1.

Option E: Directly revising the contract signed with the maintenance provider to incorporate specific environmental requirements corrects the immediate contractual omission specified in the audit finding.

Conversely, Option B (developing procurement procedures) and Option C (retraining personnel) represent corrective actions aimed at root causes to prevent future recurrence across procurement operations. Option D is unnecessary as policy commitments already encompass operational controls. Option F is an improper commercial action that does not fix the underlying documentation gap.

References: ISO 14001:2015 Clause 8.1 (Operational planning and control), Clause 10.2 (Nonconformity and corrective action), ISO 19011:2018 Clause 6.6, and CQI-IRCA ISO 14001 Lead Auditor Curriculum (Distinguishing Corrections from Corrective Actions).

Question 20 Choose 3

An internal auditor of a manufacturer of aluminium products for the car industry raised a nonconformity against section 6.2.2 of ISO 14001 in Report IA202. The nonconformity (NC3) stated:

" Top management has not analysed why none of the environmental objectives set for the last year have been met. "

A third-party auditor reviewing the internal audit process came across the nonconformity and found that no corrective action was documented. The EMS Manager confirmed no action had been taken, but added he expected a number of objectives to be achieved in the next three months, so there was no need for further action. He explained in confidence that the organisation was fighting a takeover bid and resources for environmental projects had been cut.

From the information, select three nonconformities that the auditor could raise to ISO 14001.

Show answerHide answer

Correct answer: E, F, H 10.2.a - Management failed to take corrective action to deal with the audit nonconformity.7.1 - The top management failed to provide the resources needed to meet the objectives.6.2.2 - Actions were not planned to achieve environmental objectives set by management.

Explanation

In accordance with ISO 14001:2015, audit findings must reflect direct, verifiable evidence demonstrating a failure to fulfill explicit standard requirements across resource provision, objective management, and corrective action execution.

Option E (Clause 10.2.a Nonconformity and corrective action): When an internal audit nonconformity is formally identified and reported (such as NC3 in Report IA202), Clause 10.2.a mandates that the organization react to the nonconformity and take action to control, correct, or deal with its consequences. The EMS Manager explicitly confirmed that no corrective action was taken or documented, constituting a clear nonconformity.

Option F (Clause 7.1 Resources): Top management is obligated under Clause 7.1 to determine and provide the resources necessary for the establishment, implementation, maintenance, and continual improvement of the EMS. Cutting budget and resources for environmental projects, directly causing a total failure to achieve established environmental targets, constitutes a nonconformity against resource allocation obligations.

Option H (Clause 6.2.2 Planning actions to achieve environmental objectives): Clause 6.2.2 dictates that when planning how to achieve environmental objectives, the organization must determine what will be done, what resources will be required, and how results will be evaluated. Failing to carry out planned actions to achieve objectives represents a direct failure under this clause.

The remaining options suggest speculative or overly prescriptive measures (such as notifying takeover bidders or setting new takeover-related objectives) that are not required by ISO 14001.

References: ISO 14001:2015 Clauses 6.2.2 (Planning actions to achieve environmental objectives), 7.1 (Resources), 10.2 (Nonconformity and corrective action), and CQI-IRCA ISO 14001 Lead Auditor Curriculum (Grading Audit Findings and Corrective Action Verification).

Full mock exam

Sit the ISO-14001-Lead-Auditor exam before exam day

Full-length mocks with the same number of questions and the same time limit as the real ISO-14001-Lead-Auditor exam. Every attempt draws a new set of questions from the full bank, so you can keep going until you pass comfortably.

Get full ISO-14001-Lead-Auditor mock exam
  • —questions per mock
  • —time limit
  • 95questions in the bank
  • Newmock on every attempt