Cyber AB certification · Exam CMMC-CCA

CMMC-CCA Mock Exam

Certified CMMC Assessor (CCA) Exam

Find out if you're ready for CMMC-CCA. Take the free timed mock exam and get your score in minutes, or study the free CMMC-CCA questions below with answers and explanations.

20 questions · 32 minutes · free, no sign-up

Free CMMC-CCA questions

1–10 of 44 free
Question 1 Choose 1
The audit team is discussing the OSC’s Risk Managed Assets. For these types of assets, the contractor need NOT:
Show answerHide answer

Correct answer: C Prepare for the assets to be assessed against CMMC practices.

Explanation

Explanation:
Risk Managed Assets are CMMC assets that do not process, store, or transmit CUI but can affect CUI security. Contractors must demonstrate how they manage risks from these assets, but they are not required to have these assets fully comply with all CMMC practices. Therefore, preparing them for assessment against CMMC practices is unnecessary.

Correct Option:

C — Prepare for the assets to be assessed against CMMC practices.
Risk Managed Assets are not assessed against CMMC practice requirements. Instead, the OSC must show how risks from these assets are managed via organizational policies, scoping, and network diagrams. Full compliance assessment applies only to CUI assets.

Incorrect Options:

A — Provide a network diagram of the assessment scope.
Incorrect. The OSC must include Risk Managed Assets in the network diagram to show boundaries and data flow, as per CMMC scoping guidance. Without this, risk cannot be properly evaluated.

B — Ensure they are included in the pre-assessment discussion.
Incorrect. Risk Managed Assets must be discussed pre-assessment to define how risks are managed and to clarify scope boundaries. The assessor needs this to plan validation efforts.

D — Show how they are being managed using organizational security policies.
Incorrect. This is required. The OSC must demonstrate documented policies (e.g., configuration standards, monitoring) that manage risks from these assets to prevent CUI compromise.

Reference:
CMMC Model v2.0, Level 2 Scoping Guidance, Section 3.1.2 (Risk Managed Assets). See also CMMC Assessment Guide, Asset Categories and Assessment Scope Requirements.
Question 2 Choose 1
An OSC outsources all of its security incident and event monitoring work to a third-party SOC. Additionally, the OSC utilizes a cloud-hosted antivirus (AV) system to fulfill the requirement of having virus protection without hosting additional servers on-site.

During the scoping discussion, both the SOC and AV should be listed as what type of asset?
Show answerHide answer

Correct answer: C They are Security Protection Assets due to their performance of security functions.

Explanation

Explanation:
Security Protection Assets (SPAs) are assets that provide security functions (e.g., logging, antivirus, firewalls) even if they do not directly process CUI. Since the SOC monitors incidents and the cloud AV provides virus protection, both perform security functions. They must be assessed against relevant CMMC practices that govern their operation.

Correct Option:

C — They are Security Protection Assets due to their performance of security functions.
SPAs are defined as assets that enforce or support security policies (e.g., SIEM, AV, IDS). Even when outsourced or cloud-hosted, their security function makes them SPAs. They are in-scope for practices related to their operation (e.g., incident response, malware protection).

Incorrect Options:

A — They are CUI Assets due to their operation within a CUI network.
Incorrect. CUI Assets specifically process, store, or transmit CUI. The SOC and AV system described do not directly handle CUI—they provide monitoring and protection functions. Misclassifying them as CUI Assets would unnecessarily expand assessment scope.

B — They are Out-of-Scope Assets due to being fully hosted/operated by third parties.
Incorrect. Outsourcing or cloud-hosting does not automatically remove an asset from scope. SPAs remain in-scope regardless of hosting model. The OSC must still demonstrate relevant practices (e.g., reviewing SOC reports, configuring cloud AV).

D — They are Contractor Risk Managed Assets because they are not physically or logically isolated from CUI assets.
Incorrect. Contractor Risk Managed Assets are non-CUI assets that could adversely affect CUI but are not SPAs. Since the SOC and AV explicitly perform security functions, they qualify as SPAs—not Risk Managed Assets. The description even notes they interact with CUI assets, reinforcing SPA status.

Reference:
CMMC Model v2.0, Level 2 Scoping Guidance — Asset Categories (CUI Assets, Security Protection Assets, Contractor Risk Managed Assets). See also CMMC Assessment Guide, Appendix on External Service Providers (ESPs).
Question 3 Choose 1
An OSC has a headquarters (HQ) site and satellite offices A and B. The two satellite offices are connected to the HQ through a VPN. CUI is stored within the HQ LAN room and used by staff at HQ and Site A. When categorizing assets for this assessment, assets at the HQ:
Show answerHide answer

Correct answer: A and Site A contain CUI assets and Site B is out of scope.

Explanation

Explanation:
CUI assets are defined as assets that process, store, or transmit CUI. In this scenario, CUI is stored at HQ and used by staff at HQ and Site A. Site B does not store, process, or transmit CUI—it only has VPN connectivity to HQ, which alone does not make it a CUI asset unless CUI actually flows to or through it.

Correct Option:

A — and Site A contain CUI assets and Site B is out of scope.
HQ contains the CUI storage (CUI asset). Site A staff actively use CUI, so Site A likely has CUI assets (workstations, perhaps local storage or transmission). Site B has no CUI activity described; VPN connectivity alone does not bring CUI assets into scope. Therefore, Site B can be scoped out if properly isolated.

Incorrect Options:

B — and Site A and Site B contain CUI assets since all have access to CUI.
Incorrect. VPN connectivity to HQ does not automatically mean Site B has or accesses CUI. The scenario states CUI is used at HQ and Site A only. Unless CUI is transmitted to or stored at Site B, Site B assets are not CUI assets. "Access" via VPN would need to be demonstrated.

C — contain CUI assets and Site A and Site B contain only Certification in Risk Management Assurance.
Incorrect. "Certification in Risk Management Assurance" is not a CMMC asset category. This appears to be a distractor term. The correct categories are CUI Assets, Security Protection Assets, Contractor Risk Managed Assets, and Out-of-Scope Assets.

D — and Site A contain CUI assets and Site B contains only Certification in Risk Assurance.
Incorrect. Same issue as option C—"Certification in Risk Assurance" is not a valid CMMC asset classification. Site B, if it truly has no CUI flow, would be an Out-of-Scope Asset or possibly Contractor Risk Managed Asset, not a fictional certification category.

Reference:
CMMC Model v2.0, Level 2 Scoping Guidance – Asset Categories (CUI Assets, Security Protection Assets, Contractor Risk Managed Assets, Out-of-Scope Assets). See also CMMC Assessment Guide, Determining Assessment Scope Based on CUI Flow.
Question 4 Choose 1
A CCA is asked to validate if an OSC has separated their systems containing CUI from other departments’ systems on their local network. Which of the following MUST the CCA assess?
Show answerHide answer

Correct answer: C Virtual Local Area Network (VLAN)

Explanation

Explanation:
To validate whether systems containing CUI are separated from other departments' systems on the local network, the CCA must assess mechanisms that logically segment a single physical network. VLANs are the standard technology for creating isolated broadcast domains within a local network, allowing CUI systems to be separated from non-CUI systems without requiring separate physical switches.

Correct Option:

C — Virtual Local Area Network (VLAN)
VLANs partition a single physical LAN into multiple logical networks. The CCA would assess VLAN configurations (e.g., port assignments, trunking, access control lists between VLANs) to confirm that CUI systems are isolated from other departments' systems. VLANs directly address the "local network" separation requirement.

Incorrect Options:

A — Area Network (WAN)
Incorrect. A Wide Area Network connects geographically dispersed locations (e.g., HQ to remote office). It is not a local network separation mechanism. Assessing WAN would evaluate cross-site connectivity, not separation of CUI systems from other departments within the same facility.

B — Virtual Private Network (VPN)
Incorrect. VPNs provide encrypted tunnels over untrusted networks (e.g., internet) for remote access or site-to-site connectivity. VPNs are not used to separate systems within the same local network. VPN assessment would address remote access security, not internal departmental separation.

D — Network Address Translation (NAT)
Incorrect. NAT translates IP addresses between private and public networks, primarily for internet routing and conservation of IPv4 addresses. NAT does not provide logical separation of systems within a local network. It does not prevent direct communication between departments on the same subnet.

Reference:
CMMC Level 2 Practice SC.L2-3.13.13 (Separate subnetworks for publicly accessible systems). NIST SP 800-171 Rev 2, Requirement 3.13.13. See also CMMC Assessment Guide, System and Communications Protection domain – VLANs for internal network segmentation.
Question 5 Choose 1
An OSC has built an enclave for its production environment. The enclave sits behind a firewall, with all equipment connected through a switch. There is a shipping workstation and physically connected label printer (used for the sales system, which does not process CUI) that the OSC claims are Contractor Risk Managed Assets (CRMA). Other than showing that the shipping workstation and label printer are not intended to store or transmit CUI, and documenting them in the SSP, how BEST would the OSC show that the shipping workstation and label printer are Contractor Risk Managed Assets?
Show answerHide answer

Correct answer: C Document the shipping workstation and label printer in the asset inventory; show that they are managed using the organization’s risk-based security policies and procedures; and include them in the network diagram.

Explanation

Explanation:
Contractor Risk Managed Assets (CRMA) are assets that do not process, store, or transmit CUI but can adversely affect CUI assets. The OSC must demonstrate they are managed using the organization’s own risk-based security policies and procedures, not vendor or generic industry practices. This ensures accountability and alignment with the OSC's documented security posture.

Correct Option:

C — Document in asset inventory; show management using the organization’s risk-based security policies and procedures; include in network diagram.
This is correct because CRMA status requires demonstration that the OSC applies its own risk management framework (e.g., configuration standards, patching, access controls) to these assets. Organizational policies provide auditable, repeatable control. Network diagrams and inventory documentation enable scoping and boundary verification.

Incorrect Options:

A — Document in asset inventory and include in network diagram only.
Incomplete. Simply documenting and diagramming CRMA is insufficient. The OSC must also demonstrate how these assets are managed using risk-based practices. Without showing management methods, the assessor cannot verify that risks from these assets are controlled.

B — Show management using vendor-recommended risk-based security practices.
Incorrect. Vendor recommendations are not authoritative for CMMC CRMA compliance. The OSC must apply its own organizational policies and procedures. Vendor guidance may inform but cannot replace OSC-defined, documented, and implemented risk management practices.

D — Show management using industry risk-based security best practices + include in network diagram.
Incorrect. Industry best practices (e.g., CIS benchmarks) are useful but do not substitute for the OSC’s organizational policies and procedures. CMMC requires the OSC to govern CRMA through its own documented risk management processes, not generic external standards alone.

Reference:
CMMC Model v2.0, Level 2 Scoping Guidance – Contractor Risk Managed Assets (CRMA). CMMC Assessment Guide – Asset Categorization and CRMA Requirements.
Question 6 Choose 1
During an assessment, the Lead Assessor determines certain assets to be in-scope which the OSC had considered out-of-scope.

The CCA should reply that for assets to be considered out-of-scope they:
Show answerHide answer

Correct answer: B Do not provide security protections for CUI assets.

Explanation

Explanation:
For an asset to be considered out-of-scope in a CMMC assessment, it must neither process, store, nor transmit CUI and must not provide security protections to CUI assets. If an asset provides security protections (e.g., firewall, IDS, authentication server), it becomes a Security Protection Asset (SPA) and is in-scope regardless of CUI handling.

Correct Option:

B — Do not provide security protections for CUI assets.
Out-of-scope assets must meet two conditions: (1) they do not process, store, or transmit CUI, and (2) they do not provide security protections to CUI assets. If an asset performs security functions (logging, access control, monitoring), it is a Security Protection Asset and remains in-scope even without direct CUI handling.

Incorrect Options:

A — Provide security protections to CUI assets.
Incorrect. Assets that provide security protections to CUI assets are Security Protection Assets (SPAs) and are explicitly in-scope for assessment. This describes the opposite of an out-of-scope asset. SPAs must be assessed against relevant practices.

C — Can, but are not intended to, process, store, or transmit CUI.
Incorrect. Assets that can process CUI but are not intended to (i.e., no CUI flows to them) may still be Contractor Risk Managed Assets (CRMA) or potentially out-of-scope if properly isolated. However, the key differentiator for out-of-scope is also not providing security protections. This option omits that critical condition.

D — Are not required to be physically or logically separated from CUI assets.
Incorrect. Out-of-scope assets must be physically or logically separated from CUI assets. If an asset can reach or be reached by CUI assets without controls, it cannot be out-of-scope. Lack of separation would make it a CRMA or SPA, not out-of-scope.

Reference:
CMMC Model v2.0, Level 2 Scoping Guidance – Out-of-Scope Assets definition. CMMC Assessment Guide – Asset Categorization Criteria (CUI Assets, SPAs, CRMAs, Out-of-Scope).
Question 7 Choose 1
An OSC is preparing for an assessment and wants to gather evidence that will be used by the Lead Assessor to determine the scope of the assessment. The OSC currently operates a hybrid network, with part of their infrastructure at their physical location and part of their infrastructure in a cloud environment.

What evidence should the OSC collect that would assist the Lead Assessor in determining cloud and hybrid environment constraints?
Show answerHide answer

Correct answer: D Cloud Service Provider’s Customer Responsibility Matrix

Explanation

Explanation:
For cloud and hybrid environments, the Cloud Service Provider's (CSP) Customer Responsibility Matrix clearly delineates which security controls are managed by the CSP versus the OSC. This directly informs the Lead Assessor about constraints—what the OSC is responsible for assessing versus what is inherited or must be verified via third-party assessments (e.g., FedRAMP).

Correct Option:

D — Cloud Service Provider’s Customer Responsibility Matrix
The responsibility matrix is essential for scoping a hybrid assessment. It shows which CMMC practices the OSC must fully implement, which are shared, and which are solely the CSP's responsibility. Without this, the assessor cannot determine the OSC's compliance boundaries or constraints in the cloud environment.

Incorrect Options:

A — Subnetworks list
Incorrect. A subnetworks list helps understand network segmentation but does not address cloud-specific constraints or division of responsibilities between OSC and CSP. Subnets alone reveal nothing about CSP security controls or OSC obligations.

B — System inventory
Incorrect. System inventory identifies assets but does not clarify CSP/OSC responsibility boundaries. An asset listed as "cloud VM" without a responsibility matrix leaves unknown who secures the hypervisor, physical host, or network. Inventory is necessary but insufficient for hybrid constraints.

C — Company-owned hardware list
Incorrect. This only applies to on-premises assets. In a hybrid environment, many critical assets reside in the cloud and are not company-owned. This list ignores cloud constraints entirely and provides no information about CSP-managed controls.

Reference:
CMMC Scoping Guidance – Cloud and Hybrid Environment Considerations. FedRAMP Shared Responsibility Model. CMMC Assessment Guide – External Service Provider (ESP) requirements. NIST SP 800-171 Appendix G (External Service Providers).
Question 8 Choose 1
The OSC’s network consists of a single unmanaged switch that connects all devices, including OT equipment which cannot run a vendor-supported operating system. The OSC correctly scoped the OT equipment as a Specialized Asset, listed it in their inventory and SSP, and provided a network diagram showing plans to isolate the OT and apply additional security measures. What information does the Lead Assessor still require to ensure compliance?
Show answerHide answer

Correct answer: D Evidence that the network isolation is completed by the end of the assessment as well as supporting evidence for all other applicable CMMC practices

Explanation

Explanation:
For a Specialized Asset (OT equipment with unsupported OS), the OSC must provide evidence that planned mitigations (network isolation, additional security measures) are actually implemented, not just documented as plans. The Lead Assessor needs proof that isolation is completed before or during the assessment, plus evidence for all applicable CMMC practices that the OSC claims are met.

Correct Option:

D — Evidence that the network isolation is completed by the end of the assessment as well as supporting evidence for all other applicable CMMC practices.
Plans and diagrams are insufficient. The OSC must demonstrate implementation. Network isolation must be completed (not just planned) by assessment end. Additionally, all other CMMC practices applicable to this Specialized Asset (e.g., access controls, audit, configuration management) require supporting evidence.

Incorrect Options:

A — Installation and configuration documentation for the OT to ensure it was correctly built.
Insufficient. While configuration documentation may be part of evidence, the critical missing element is proof that isolation and additional security measures are implemented. Installation docs alone do not verify network isolation or risk management execution.

B — Wording in the scoping document detailing how the OT adheres to all other applicable CMMC practices.
Incorrect. Wording (text in a document) is not evidence of implementation. The OSC already provided a plan. More descriptive wording does not prove execution. Assessors need objective evidence (configurations, logs, interviews), not additional narrative.

C — Wording in the SSP detailing how the OT is managed using the OSC’s risk-based security policies.
Incorrect. The SSP already documents plans. Additional wording does not close the gap between planning and implementation. Evidence of actual management (e.g., patching logs, access reviews, monitoring) is required, not more policy language.

Reference:
CMMC Scoping Guidance – Specialized Assets (OT, legacy systems). CMMC Assessment Guide – Evidence Requirements for Specialized Assets. NIST SP 800-171 Requirement 3.11.3 (Plan of action).
Question 9 Choose 1
While scoping the assessment, the assessor learns that the OSC uses various cloud-based solutions sporadically as part of its normal course of business. The OSC states that most business is conducted onpremises and that only a small amount of business uses the cloud. The OSC thinks the cloud is only used for system backups, but there are isolated exceptions.

Are the data provided sufficient to determine that the OSC limits connection to external information systems?
Show answerHide answer

Correct answer: B No, the OSC did not fully define the extent external connections are used.

Explanation

Explanation:
To determine if the OSC limits connections to external information systems (SC.L2-3.13.1), the assessor needs a complete and precise definition of all external connections—their purpose, frequency, data types, and security controls. The OSC provided vague statements ("sporadically," "isolated exceptions," "small amount of business") without fully defining the extent, which is insufficient.

Correct Option:

B — No, the OSC did not fully define the extent external connections are used.
The OSC's response lacks specificity. "Sporadic," "isolated exceptions," and "small amount" are not measurable or verifiable. The assessor cannot determine if external connections are properly limited without a complete inventory of cloud services, their business purposes, data flows (including CUI), and applicable security controls.

Incorrect Options:

A — No, the OSC stated most of its business is on-premises.
Incorrect. The fact that most business is on-premises does not address the insufficiency. The problem is undefined extent of external connections, not the proportion of on-premises versus cloud. An undefined small number of external connections still cannot be assessed for limitation controls.

C — Yes, the OSC confirmed that external connections occur.
Incorrect. Confirming that external connections exist does not satisfy the requirement to determine if they are limited. The practice requires assessment of controls that restrict and manage external connections. Simply knowing they occur provides no basis to evaluate limitation.

D — Yes, the OSC confirmed that external connections occur for system backups.
Incorrect. Even if backups are one purpose, the OSC admits "isolated exceptions" for other cloud use. These exceptions are undefined. The assessor cannot determine limitation without knowing all external connection types, including exceptions. Partial information is insufficient.

Reference:
CMMC Level 2 Practice SC.L2-3.13.1 (Limit connections to external information systems). NIST SP 800-171 Rev 2, Requirement 3.13.1. CMMC Assessment Guide – External Connection Scoping and Documentation Requirements.
Question 10 Choose 1
The Lead Assessor is planning to conduct an assessment for an OSC. The Assessor has been given a preliminary asset inventory list by the OSC. How would the Lead Assessor determine if any assets are outof- scope for the assessment?
Show answerHide answer

Correct answer: C Assets cannot process, store, or transmit CUI because they are physically or logically separated from CUI assets, or they are inherently unable to do so.

Explanation

Explanation:
For an asset to be considered out-of-scope, it must be unable to process, store, or transmit CUI—either because it is physically/logically separated from CUI assets (e.g., air-gapped network, separate VLAN with no routing) or inherently incapable (e.g., label printer with no persistent storage). The Lead Assessor verifies these conditions against the asset inventory.

Correct Option:

C — Assets cannot process, store, or transmit CUI because they are physically or logically separated from CUI assets, or they are inherently unable to do so.
This correctly states the out-of-scope criteria. Physical/logical separation ensures no CUI flow. Inherent inability (e.g., device lacks storage or network connectivity) also qualifies. The assessor reviews network diagrams, configurations, and device capabilities to confirm these conditions for each claimed out-of-scope asset.

Incorrect Options:

A — All assets in an OSC’s inventory fall within the scope.
Incorrect. Not all assets are automatically in-scope. CMMC allows out-of-scope assets if they meet separation or inherent inability criteria. Claiming all assets are in-scope ignores legitimate scoping exclusions and would unnecessarily expand assessment scope.

B — None of the assets in an OSC’s inventory fall within the scope.
Incorrect. This is false. Assets that process, store, or transmit CUI (CUI Assets) are always in-scope. Security Protection Assets are also in-scope. Many or most assets in an inventory typically fall within scope for a CMMC assessment.

D — Out-of-Scope Assets can process, store, or transmit CUI because they do not need to be physically or logically separated.
Incorrect. This is the opposite of the correct definition. If an asset can process, store, or transmit CUI, it cannot be out-of-scope. Out-of-scope assets must be incapable of doing so. No exception exists for lack of separation.

Reference:
CMMC Model v2.0, Level 2 Scoping Guidance – Out-of-Scope Assets definition and criteria. CMMC Assessment Guide – Asset Categorization and Scope Determination.
Full mock exam

Sit the CMMC-CCA exam before exam day

Full-length mocks with the same number of questions and the same time limit as the real CMMC-CCA exam. Every attempt draws a new set of questions from the full bank, so you can keep going until you pass comfortably.

Get full CMMC-CCA mock exam
  • 150questions per mock
  • 240 mintime limit
  • 150questions in the bank
  • Newmock on every attempt

CMMC-CCA - Certified CMMC Assessor (CCA) Exam Official Exam Blueprint and Weight:


1. CMMC Framework and Assessment Methodology

Official Exam Weight: 20-25%

Subtopics: Understand the Cybersecurity Maturity Model Certification (CMMC) framework, identify CMMC assessment objectives, understand CMMC levels and domains, interpret CMMC assessment guides, understand assessment scope requirements, identify assessment phases and procedures, review assessment documentation requirements, apply CMMC assessment methodology, identify evidence collection techniques, understand assessor roles and responsibilities, apply ethical assessment practices, understand confidentiality and conflict of interest requirements, identify documentation and reporting standards.

2. Governance Risk and Compliance (GRC)

Official Exam Weight: 15-20%

Subtopics: Implement governance frameworks, assess organizational cybersecurity policies, identify compliance requirements for Department of Defense (DoD) contractors, evaluate risk management processes, assess security awareness and training programs, identify regulatory and contractual requirements, review incident response policies, assess business continuity and disaster recovery planning, evaluate third-party risk management, understand legal and compliance obligations, identify remediation and corrective action processes.

3. Security Controls Assessment

Official Exam Weight: 35-40%

Subtopics: Assess access control implementation, evaluate audit and accountability controls, assess configuration management practices, review identification and authentication controls, assess incident response capabilities, evaluate maintenance and media protection controls, assess personnel security requirements, evaluate physical protection measures, assess recovery and contingency planning, review risk assessment processes, assess security assessment and authorization controls, evaluate system and communications protection, assess system and information integrity controls, review vulnerability management processes, validate multifactor authentication and encryption controls.

4. Assessment Execution and Reporting

Official Exam Weight: 15-20%

Subtopics: Conduct assessment planning activities, perform evidence validation, interview stakeholders and technical personnel, document assessment findings, identify gaps and deficiencies, evaluate implementation effectiveness, prepare assessment reports, communicate assessment outcomes, develop recommendations and remediation guidance, maintain assessment records, manage assessment timelines and deliverables, perform quality assurance reviews, handle disputes and clarification requests.

5. Technical Security and Cybersecurity Fundamentals

Official Exam Weight: 10-15%

Subtopics: Understand network security concepts, identify common cyber threats and attack vectors, understand secure system architecture principles, review cloud security concepts, identify endpoint security controls, understand identity and access management (IAM), review encryption and cryptography fundamentals, understand vulnerability scanning and penetration testing concepts, identify logging and monitoring practices, review security operations center (SOC) functions, understand incident detection and response fundamentals.



Domain Title Exam Weight
1 CMMC Framework and Assessment Methodology 20-25%
2 Governance Risk and Compliance (GRC) 15-20%
3 Security Controls Assessment 35-40%
4 Assessment Execution and Reporting 15-20%
5 Technical Security and Cybersecurity Fundamentals 10-15%