Which heat recovery device listed below can be used to preheat boiler make-up water
using the heat energy from skimming blowdown?
Show answerHide answer
Correct answer: AShell and tube heat exchanger
Question 32Choose 1
A steam trap with a 6-mm orifice in an 0.8-MPa steam system has failed open. The steam
system is pressurized8.760 hours/yr. The steam cost is $15.00 /GJ. Using thetable below,
what is the annualcost of the vented steam through the failed steam trap? ignore any
condensate return issues.
[The question from the previous image, which was about calculating the annual cost of heat
loss through a wall, but had a discrepancy between the calculated cost and the provided
answer choices]
Show answerHide answer
Correct answer: D$30,000/yr
Question 33Choose 1
An energy project implemented today saves $10,000 per year for the next 20 years. Using
the 5% interest table, determine the total value of savings at the end of the 20th year?
Show answerHide answer
Correct answer: E$496,991
Question 34Choose 1
Lighting systems operate with a certain recoverable light loss factor. Control systems with
photocell sensor inputs combined with dimming ballasts can be used to regulate dimming
levels to maintain a continuous light level in the work space. Which of the following best
describes this type of control?
Show answerHide answer
Correct answer: AClosed-loop controller
Question 35Choose 1
In a performance contract, which group has the greatest investment risk?
Show answerHide answer
Correct answer: BThe energy-service company
Question 36Choose 1
What is the best type of heat exchanger to recover and transfer latent heat energy from
one air stream to another?
Show answerHide answer
Correct answer: DDesiccant heat wheel
Question 37Choose 1
A three phase, 380-volt system, has the following voltage measurements:
Va = 375 volts
Vb = 380 volts
Vc = 391 volts
Calculate the percent voltage imbalance.
Show answerHide answer
Correct answer: B2.4%
Question 38Choose 1
If the temperature difference across an external wall is 20°C and the heat flow across the
wall is 2.5 Watts/m², calculate the insulation value of the wall (including inside and outside
air films)?
Show answerHide answer
Correct answer: CR = 8 m²-°C/W
Question 39Choose 1
A concentrating solar thermal system collects 5 GJ/h of thermal heat, which is delivered to
a 94% efficient hot water generator. The hot water generator is used to raise the water
temperature from 15°C to 65°C. The specific heat of water (Cp) is 4.2 kJ/kg-°C. What flow
rate (liter/second) of hot water can be delivered from the hot water generator?
Show answerHide answer
Correct answer: C9.2 liter/second