Show answerHide answer
Correct answer: C Replace both failed drives at the same time.
Explanation
ExplanationThe key facts in the scenario are:
Two drives have failed, but they are in different RAID 1 arrays.
The server is mission-critical (implying minimizing downtime is vital).
The drives are hot-swappable (meaning the replacement can be performed while the server is running).
The Most Efficient Choice (C)
Since the two failed drives belong to separate, independent RAID 1 arrays, replacing both simultaneously is the most efficient and safe action.
Safety:
Each RAID 1 array (which is a mirror) still has its good, functional mirror drive intact. The failure of the drive in Array A has no bearing on the status of Array B's good drive, and vice versa. There is no risk of losing data on a second array during the first array's rebuild process.
Efficiency:
Replacing both failed drives at the same time minimizes the administrator's physical labor and allows the hardware RAID controller to initiate the rebuild process for both arrays concurrently. This cuts the total time required for the system to return to a fully redundant state compared to waiting for one array to rebuild before starting the second.
Why the Other Options are Incorrect
A. Replace one drive, wait for a rebuild, and replace the next drive:
This is the standard, conservative best practice when dealing with a single degraded array (like a RAID 5/6) or when two drives have failed in the same RAID 10 group to ensure no further failures occur during the rebuild. However, since the failures are in separate, independent RAID 1 arrays, this approach is unnecessarily time-consuming and inefficient.
B. Shut down the server and replace the drives:
Since the drives are hot-swappable, shutting down a mission-critical server is a major, unnecessary disruption that increases downtime, making this the least efficient option.
D. Replace all the drives in both degraded arrays:
This is excessive and costly. Only the failed drives need to be replaced to restore redundancy. Replacing the still-working drives is a waste of time and money, especially if they have not reported any errors.