Cisco certification · Exam 300-710

300-710 Mock Exam

Securing Networks with Cisco Firepower (300-710 SNCF)

Free 300-710 questions on Topic 3: Management and Troubleshooting, each with the answer and an explanation.

20 questions · 33 minutes · free, no sign-up

Topic 3: Management and Troubleshooting questions

1–7 of 7 free
Question 1 Choose 1
Which action should be taken after editing an object that is used inside an access control policy?
Show answerHide answer

Correct answer: C Redeploy the updated configuration

Explanation

Explanation

In Cisco FMC, after editing an object referenced by an active access control policy, simply saving the object does not push the changes to the managed devices. The modified configuration must be redeployed for the changes to take effect on the FTD devices. Cisco's official documentation explicitly states that if an active policy references the edited object, configuration changes must be deployed. When editing an object group used in an access control policy, you must redeploy the changed configuration for the changes to take effect.

Why the Other Options Are Incorrect

A. Delete the existing object in use: This is incorrect and may cause deployment failures. Cisco documentation notes that you cannot delete a group that is in use in an active policy. Removing objects that are still referenced can also create configuration inconsistencies.

B. Refresh the Cisco FMC GUI for the access control policy: Refreshing the GUI only updates the displayed information. It does not push configuration changes to the managed devices.

D. Create another rule using a different object name: This is unnecessary and does not address the requirement. The correct workflow is to edit the existing object and redeploy the configuration, rather than create duplicate rules.

Reference

Cisco Secure Firewall Management Center Device Configuration Guide — Object Management: If an active policy references an object, deploy the configuration changes. When editing an object group used in a policy, redeploy the configuration for the changes to take effect.
Question 2 Choose 1
Which command is entered in the Cisco FMC CLI to generate a troubleshooting file?
Show answerHide answer

Correct answer: D sudo sf_troubleshoot.pl

Explanation

Explanation

On the FMC, the sf_troubleshoot.pl script is the command-line tool used to generate a troubleshooting file. It collects system logs, configuration data, and diagnostic output into a compressed archive, typically saved under /var/common/, that can be sent to Cisco TAC. It is run from the FMC's Linux shell with root privileges, hence the use of sudo. Similar troubleshooting files can also be generated through the GUI under System > Health > Monitor > Advanced Troubleshooting.

Why the Other Options Are Incorrect

A. show running-config: This command displays the device's active configuration. It does not generate a troubleshooting archive and is not the FMC Linux shell command used for this purpose.

B. show tech-support chassis: This is an FXOS command for Firepower 4100/9300 chassis. It is run on the chassis supervisor, not on the FMC.

C. system support diagnostic-cli: This is an FTD CLI command that opens the diagnostic CLI on a threat defense device. It does not run on the FMC to generate a troubleshooting file.

Reference

- Cisco Secure Firewall Management Center Administration Guide: Troubleshooting and Advanced Troubleshooting (Generate Troubleshooting Files)
- Cisco TAC documentation: Generate Troubleshooting Files on Firepower Devices
Question 3 Choose 1
After deploying a network-monitoring tool to manage and monitor networking devices in your organization, you realize that you need to manually upload an MIB for the Cisco FMC. In which folder should you upload the MIB file?
Show answerHide answer

Correct answer: C /etc/sf/DCEALERT.MIB

Explanation

Explanation

Cisco's official documentation states that if your network management system requires the Management Information Base (MIB) file for the Secure Firewall Management Center (FMC), you can obtain it from the FMC at the path /etc/sf/DCEALERT.MIB. This file contains definitions for SNMP traps and alerts sent by the FMC. It allows network monitoring tools to properly interpret and process the alerts generated by the FMC.

Why the Other Options Are Incorrect

A. /etc/sf/DCMIB.ALERT: The filename does not match the official documentation. Cisco specifies DCEALERT.MIB, not DCMIB.ALERT.

B. /sf/etc/DCEALERT.MIB: The directory order is incorrect. The documented path starts with /etc/sf/, not /sf/etc/.

D. system/etc/DCEALERT.MIB: This path does not match the documented location. The correct path is /etc/sf/DCEALERT.MIB.

Reference

Cisco Secure Firewall Management Center documentation — Intrusion SNMP Alert Options: If a network management system requires an MIB file, it can be obtained from the Secure Firewall Management Center at /etc/sf/DCEALERT.MIB. This location is also referenced in the Create an SNMP Alert Response documentation.
Question 4 Choose 1
Which command-line mode is supported from the Cisco Firepower Management Center CLI?
Show answerHide answer

Correct answer: C configuration

Explanation

Explanation

The Cisco Firepower Management Center (FMC) CLI officially defines four modes: the default CLI Management mode, plus system, show, and configure modes. Among the options, configuration corresponds to the configure mode, which provides supported commands for configuring and managing system operations, such as changing passwords and generating troubleshooting files.

Why the Other Options Are Incorrect

A. Privileged: Privileged EXEC is a command mode associated with the Cisco Firepower Threat Defense (FTD) diagnostic CLI, not the FMC CLI.

B. User: User EXEC is also associated with the FTD diagnostic CLI and is not an FMC CLI mode.

D. Admin: Admin is a username, commonly used for the default administrator account, not a command-line mode. After logging into FMC, the prompt may display admin@FMC:, but the mode itself is not named admin.

Reference

Cisco Firepower Management Center Administration Guide — Firepower Management Center CLI Modes: The CLI includes four modes, with commands in the system, show, and configure modes beginning with the corresponding mode name.
Question 5 Choose 2
A network engineer is configuring URL Filtering on Firepower Threat Defense. Which two port requirements on the Firepower Management Center must be validated to allow communication with the cloud service? (Choose two.)
Show answerHide answer

Correct answer: A, E outbound port TCP/443outbound port TCP/80

Explanation

Explanation

To allow the Firepower Management Center (FMC) to communicate with Cisco cloud services for URL Filtering, the FMC requires outbound access on both TCP/443 (HTTPS) and TCP/80 (HTTP). According to Cisco's official communication port documentation, the FMC uses these ports to retrieve URL category and reputation data and perform lookups for uncategorized URLs. Port 443 supports secure HTTPS communication, while port 80 is also listed as a requirement for retrieving URL category and reputation data.

Why the Other Options Are Incorrect

B. Inbound port TCP/80: The FMC initiates the connection to the cloud service. It does not need to accept inbound HTTP traffic for this function.

C. Outbound port TCP/8080: Port 8080 is not listed as a required port for FMC-to-cloud URL Filtering communication in the referenced Cisco documentation.

D. Inbound port TCP/443: Although the FMC may accept inbound HTTPS connections for management access, URL Filtering cloud communication is initiated outbound by the FMC. Therefore, inbound TCP/443 is not the requirement described in the question.

Reference

Cisco Firepower Management Center Configuration Guide — Security, Internet Access, and Communication Ports: The communication ports documentation lists TCP/443 and TCP/80 for the Management Center to obtain URL category and reputation data.
Question 6 Choose 1
Which report template field format is available in Cisco FMC?
Show answerHide answer

Correct answer: C bar chart

Explanation

Explanation

According to Cisco's official Firepower Management Center (FMC) documentation, the available field format options for report templates include bar charts, line charts, pie charts, table views, and detail views. Among the options, Bar Chart is a supported chart format used to compare the number of records matching specific attributes.

Why the Other Options Are Incorrect

A. Box lever chart: This is not a chart type supported by FMC report templates. Cisco documentation does not list this format.

B. Arrow chart: This is not a supported format option in FMC report templates.

D. Benchmark chart: This is not a chart type listed for FMC reports in the official documentation.

Reference

Cisco Secure Firewall Management Center Administration Guide — Report Template Fields: The Format options include Bar Chart, Line Chart, Pie Chart, Table View, and Detail View.
Question 7 Choose 1
Which command must be run to generate troubleshooting files on an FTD?
Show answerHide answer

Correct answer: C system generate-troubleshoot all

Explanation

Explanation

According to Cisco's official documentation, to generate a troubleshooting file on a Firepower Threat Defense (FTD) device through the CLI, use the command system generate-troubleshoot all. This command runs in the FTD CLI and produces a troubleshooting file containing logs, configuration data, and command output for analysis by Cisco Technical Assistance Center (TAC).

The command syntax is system generate-troubleshoot option1 optionN, where options can include ALL, SNT, PER, SYS, NET, and others. Specifying all collects all available troubleshooting data. After execution, the file is saved to a location such as /ngfw/var/common/results-xxxxx.tar.gz or /var/common/xxxxxx.tar.gz, depending on the platform and software version.

Why the Other Options Are Incorrect

A. system support view-files: This is not the documented FTD CLI command for generating troubleshooting files.

B. sudo sf_troubleshoot.pl: This command is used on the Firepower Management Center (FMC), not on the FTD device itself. Cisco documentation distinguishes the FMC command sudo sf_troubleshoot.pl from the FTD command system generate-troubleshoot all.

D. show tech-support: This command is associated with diagnostic collection in environments such as FXOS, the chassis operating system on platforms like Firepower 4100/9300. It is not the standard FTD CLI command for generating the troubleshooting archive described in the question.

Reference

Cisco Firepower Threat Defense Command Reference: system generate-troubleshoot is documented as the command to generate troubleshooting data for analysis by Cisco Technical Support, with ALL as an option to run all available data collection types.

That's the last free question in Topic 3: Management and Troubleshooting

You've seen the free 30% (7 of 25 questions). Full access unlocks every question and full-length 300-710 mock exams (55 questions, 90 minutes), a different mock on every attempt.

Unlock full mock exam
Full mock exam

Sit the 300-710 exam before exam day

Full-length mocks with the same number of questions and the same time limit as the real 300-710 exam. Every attempt draws a new set of questions from the full bank, so you can keep going until you pass comfortably.

Get full 300-710 mock exam
  • 55questions per mock
  • 90 mintime limit
  • 420questions in the bank
  • Newmock on every attempt